Solar Inverter - 100KW - ON GRID - SUNGROW

Solar Inverter - 100KW - ON GRID - SUNGROW
Regular price $6,500.00 Sale price $5,800.00

SUNGROW

Clean power for all

Multi-MPPT String Inverter For 1000 Vdc System SG 110CX

WITH WIFI

 Type designation
SG110CX
Input (DC)
Max. PV Input Voltage 1100 V**
Min. PV Input Voltage / Start-up input voltage 200V / 250V
Nominal PV input voltage 585V
MPPT voltage range 1000-200V
No. of independent MPP Inputs 9
No. of PV Strings per MPPT 2
Max. PV Input Current 26 A*9
Max. DC short-circuit current 40 A*9
Output (AC)
AC output power 110KVA @ 45 C / 100KVA @ 50 C
Max. AC output current 158.8A
Nominal AC voltage 3/N/PE, 400V
AC voltage range 460-320V
Nominal grid frequency / Grid frequency range 50Hz/55-45Hz, 60Hz/65-55Hz
Harmonic (THD) <3% (at nominal power)
Power Factor at nominal power / Adjustable power factor >0.8/0.99 leading - 0.8 lagging
Feed-in phases / AC connection -3/3PE
Efficiency
Max. efficiency
98.7%
European efficiency
98.5%
Protection and Function
DC reverse polarity protection
Yes
AC short-circuit protection Yes
Leakage current protection
Yes
Grid monitoring Yes
Ground Fault monitoring
Yes
DC switch
Yes
AC switch No
PV string monitoring Yes
Q at night function Yes
PID recovery function Yes
Arc fault circuit Interrupter (AFCI) Optional
Surge protection DC Type II (Optional: Type I + 10 / AC Type II)
General Data
Dimensions (W*H*D) 362.5*660*1051mm
Weight 89kg
Topology Transformerless
Ingress protection rating IP66
Night power consumption < 2 W
Operating ambient temperature range 30- TO 60 C (>50 C derating)
Allowable relative humidity range 100-0%
Cooling method Smart forced air cooling
Max. operating altitude 4000m (>3000m derating)
Display LED, Bluetooth+APP
Communication RS485/Optional: WLAN, Ethernet
DC connection type MC4 (max. 10mm2 optional)
AC connection type OT/DT terminal (Max. 240mm2
Complance IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4120:2018, EN 2/1 -50549, AS/NZS 4777,2:2015, CEI 2019 16-0, VDE 1-1-0126/A1, VFR 2019, UTE C1:2013-712-15, DEWA, UNE
Grid support Q at night function, LVRT, HVRT, active & reactive power control and power rampe rate control

SUNGROW

Clean power for all

Multi-MPPT String Inverter For 1000 Vdc System SG 110CX

WITH WIFI

 Type designation
SG110CX
Input (DC)
Max. PV Input Voltage 1100 V**
Min. PV Input Voltage / Start-up input voltage 200V / 250V
Nominal PV input voltage 585V
MPPT voltage range 1000-200V
No. of independent MPP Inputs 9
No. of PV Strings per MPPT 2
Max. PV Input Current 26 A*9
Max. DC short-circuit current 40 A*9
Output (AC)
AC output power 110KVA @ 45 C / 100KVA @ 50 C
Max. AC output current 158.8A
Nominal AC voltage 3/N/PE, 400V
AC voltage range 460-320V
Nominal grid frequency / Grid frequency range 50Hz/55-45Hz, 60Hz/65-55Hz
Harmonic (THD) <3% (at nominal power)
Power Factor at nominal power / Adjustable power factor >0.8/0.99 leading - 0.8 lagging
Feed-in phases / AC connection -3/3PE
Efficiency
Max. efficiency
98.7%
European efficiency
98.5%
Protection and Function
DC reverse polarity protection
Yes
AC short-circuit protection Yes
Leakage current protection
Yes
Grid monitoring Yes
Ground Fault monitoring
Yes
DC switch
Yes
AC switch No
PV string monitoring Yes
Q at night function Yes
PID recovery function Yes
Arc fault circuit Interrupter (AFCI) Optional
Surge protection DC Type II (Optional: Type I + 10 / AC Type II)
General Data
Dimensions (W*H*D) 362.5*660*1051mm
Weight 89kg
Topology Transformerless
Ingress protection rating IP66
Night power consumption < 2 W
Operating ambient temperature range 30- TO 60 C (>50 C derating)
Allowable relative humidity range 100-0%
Cooling method Smart forced air cooling
Max. operating altitude 4000m (>3000m derating)
Display LED, Bluetooth+APP
Communication RS485/Optional: WLAN, Ethernet
DC connection type MC4 (max. 10mm2 optional)
AC connection type OT/DT terminal (Max. 240mm2
Complance IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4120:2018, EN 2/1 -50549, AS/NZS 4777,2:2015, CEI 2019 16-0, VDE 1-1-0126/A1, VFR 2019, UTE C1:2013-712-15, DEWA, UNE
Grid support Q at night function, LVRT, HVRT, active & reactive power control and power rampe rate control
  • PV1800 VPM Series High Frequency Off Grid Solar Inverter (1KW)
  • Pure sine wave output
  • Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
  • Bult in MPPT 60A solar charge controller
  • Combining solar system, AC utility, and battery power source to supply continuous power
  • Overload, short circuit and Deep discharge protection
  • Cold start function
  • Support USB, RS485 monitoring function
  • WIFI remote monitoring (optional)
  • Compatible to generator

 

MODEL PV18-1012 VPM
Default Battery System Voltage 12VDC
INVERTER OUTPUT
Rated Power 1000VA / 1000W
Surge Power 2000VA
Waveform Pure sine wave
AC Voltage Regulation (Batt.Mode) 220VAC~240VAC(Setting)
Inverter Efficiency(Peak) 90%~93%
Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
Frequency Range 50Hz / 60Hz (Auto sensing)
BATTERY
Normal voltage 12VDC
Floating Charge Voltage 13.7VDC
Overcharge Protection 15VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage 75VDC
PV Array MPPT Voltage Range 15~75VDC
Standby Power Consumption 2W
Maximum PV Array Power 625W
Maximum Solar Charge Current
Maximum Efficiency 98%
Maximum AC Charge Current 10A or 20A
Maximum Charge Current 70A
MECHANICAL SPECIFICATIONS
Machine Dimensions (W*H*D)(mm) 225*355*92
Package Dimensions (W*H*D)(mm) 410*300*78
Net Weight(kg) 5
Gross Weight(kg) 5.5
OTHER
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Operating Temperature 0°C~50°C
Storage Temperature -15°C -60°C


  • Solar Inverter - 3KW - OFF GRID - MUST VPM
    Translation missing: en.products.product.regular_price $200.00
    • MUST ORIGINAL
    • Solar Inverter:
    • Model Name: PV1800
    • MD: PH18-3024 VPM
    • Operating Temp. Range: -10c ~50c
    • Protection Class: Class I
    • Protection Degree: IP 20
    • INVERTER MODE:
    • Rated Power: 3000VA/3000W
    • DC Input: 24VDC, 130A
    • AC Output: 220VAC, 50HZ 13A
    • Output Power Factor: 1.0
    • AC Charger Mode:
    • AC Input: 220VAC, 50Hz 17.7A
    • DC Output: 27VDC, 30/20A
    • Solar Charger Mode:
    • Rated Power: 60A
    • System Current: 24VDC
    • MPPT Volt Range: 30-120VDC
    • Max. Solar Volt (VOC): 145VDC
    • Max Charge Current: 80A
  • Solar Inverter - 3kw Off Grid - MUST
    Translation missing: en.products.product.regular_price $285.00
  • Solar Inverter- OFF Grid Hybrid - MUST 5.2KVA
    Translation missing: en.products.product.regular_price $300.00
  • Solar Inverter- OFF Grid -MUST 10kw
    Translation missing: en.products.product.regular_price $720.00
  • Solar Inverter- On/OFF Grid -MUST 3 KW
    Translation missing: en.products.product.regular_price $400.00
  • Login