Inverter - 6KW - Hybrid - on/off grid - Deye

Inverter - 6KW - Hybrid - on/off grid  - Deye
Regular price $1,550.00 Sale price $1,375.00

DEYE LB version

Hybrid Inverter ON/OFF GRID

SUN-6K-SG05LP-1EU

INCLUDING WIFI/PARALLEL KIT

Model
SUN6-K-SG05LP-1EU
Battery Input Data
Battery Type Lead-acid or Li-Ion
Battery Voltage Range (V) 60~40
Max. Charging Current (A) 135
Max. Discharging Current (A) 135
External Temperature Sensor Yes
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 7800
Rated PV Input Voltage (V) 500~125)370)
Start-up Voltage (V) 125
MPPT Voltage Range (V) 425-150
Full Load DC Voltage Range (V) 425-300
PV Input Current (A) 13+13
Max. PV ISC (A) 17+17
Number of MPPT/Strings per MPPT 1+1/2
AC Output Data
Rated AC Output and UPS Power (W) 6000
Max. AC Output Power (W) 6600
AC Output Rated Current (A) 27.3
Max. AC Current (A) 30
Max. Continuous AC Passthrought (A) 40
Peak Power (off grid) 2 time of rated power, 10$
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 60/50Hz; L/N/PE 230/220Vac (single phase)
Grid Type Single Phase
DC Injection current (mA) THD<%3 (Linear load<%1.50
Efficiency
Max. Efficiency %97.60
Euro. Efficiency %97.00
MPPT Efficiency %99.90
Protection
Integrated PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, insulation Resistor Detection, Residual current monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection
Output Over Voltage Protection DC Type II / AC Type III
Certifications and Standards
Grid Regulation CEI 21-0, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 1-1-0126, RD 1699, C11-10
Safety EMC/Standard IEC/EN 4/3/2/1-6-61000, IEC/EN 1-62109, IEC/EN 2-62109
General Data
Operating Temperature Range 60~45 , >45 derating
Cooling Natural cooling
Noise (db) <30db
Communication with BMS RS485; CAN
Weight (kg) 24
Size (mm) 330W x 580H x 232D
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 years

DEYE LB version

Hybrid Inverter ON/OFF GRID

SUN-6K-SG05LP-1EU

INCLUDING WIFI/PARALLEL KIT

Model
SUN6-K-SG05LP-1EU
Battery Input Data
Battery Type Lead-acid or Li-Ion
Battery Voltage Range (V) 60~40
Max. Charging Current (A) 135
Max. Discharging Current (A) 135
External Temperature Sensor Yes
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 7800
Rated PV Input Voltage (V) 500~125)370)
Start-up Voltage (V) 125
MPPT Voltage Range (V) 425-150
Full Load DC Voltage Range (V) 425-300
PV Input Current (A) 13+13
Max. PV ISC (A) 17+17
Number of MPPT/Strings per MPPT 1+1/2
AC Output Data
Rated AC Output and UPS Power (W) 6000
Max. AC Output Power (W) 6600
AC Output Rated Current (A) 27.3
Max. AC Current (A) 30
Max. Continuous AC Passthrought (A) 40
Peak Power (off grid) 2 time of rated power, 10$
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 60/50Hz; L/N/PE 230/220Vac (single phase)
Grid Type Single Phase
DC Injection current (mA) THD<%3 (Linear load<%1.50
Efficiency
Max. Efficiency %97.60
Euro. Efficiency %97.00
MPPT Efficiency %99.90
Protection
Integrated PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, insulation Resistor Detection, Residual current monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection
Output Over Voltage Protection DC Type II / AC Type III
Certifications and Standards
Grid Regulation CEI 21-0, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 1-1-0126, RD 1699, C11-10
Safety EMC/Standard IEC/EN 4/3/2/1-6-61000, IEC/EN 1-62109, IEC/EN 2-62109
General Data
Operating Temperature Range 60~45 , >45 derating
Cooling Natural cooling
Noise (db) <30db
Communication with BMS RS485; CAN
Weight (kg) 24
Size (mm) 330W x 580H x 232D
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 years
  • PV1800 VPM Series High Frequency Off Grid Solar Inverter (1KW)
  • Pure sine wave output
  • Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
  • Bult in MPPT 60A solar charge controller
  • Combining solar system, AC utility, and battery power source to supply continuous power
  • Overload, short circuit and Deep discharge protection
  • Cold start function
  • Support USB, RS485 monitoring function
  • WIFI remote monitoring (optional)
  • Compatible to generator

 

MODEL PV18-1012 VPM
Default Battery System Voltage 12VDC
INVERTER OUTPUT
Rated Power 1000VA / 1000W
Surge Power 2000VA
Waveform Pure sine wave
AC Voltage Regulation (Batt.Mode) 220VAC~240VAC(Setting)
Inverter Efficiency(Peak) 90%~93%
Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
Frequency Range 50Hz / 60Hz (Auto sensing)
BATTERY
Normal voltage 12VDC
Floating Charge Voltage 13.7VDC
Overcharge Protection 15VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage 75VDC
PV Array MPPT Voltage Range 15~75VDC
Standby Power Consumption 2W
Maximum PV Array Power 625W
Maximum Solar Charge Current
Maximum Efficiency 98%
Maximum AC Charge Current 10A or 20A
Maximum Charge Current 70A
MECHANICAL SPECIFICATIONS
Machine Dimensions (W*H*D)(mm) 225*355*92
Package Dimensions (W*H*D)(mm) 410*300*78
Net Weight(kg) 5
Gross Weight(kg) 5.5
OTHER
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Operating Temperature 0°C~50°C
Storage Temperature -15°C -60°C


  • Solar Inverter - 3KW - OFF GRID - MUST VPM
    Translation missing: en.products.product.regular_price $200.00
    • MUST ORIGINAL
    • Solar Inverter:
    • Model Name: PV1800
    • MD: PH18-3024 VPM
    • Operating Temp. Range: -10c ~50c
    • Protection Class: Class I
    • Protection Degree: IP 20
    • INVERTER MODE:
    • Rated Power: 3000VA/3000W
    • DC Input: 24VDC, 130A
    • AC Output: 220VAC, 50HZ 13A
    • Output Power Factor: 1.0
    • AC Charger Mode:
    • AC Input: 220VAC, 50Hz 17.7A
    • DC Output: 27VDC, 30/20A
    • Solar Charger Mode:
    • Rated Power: 60A
    • System Current: 24VDC
    • MPPT Volt Range: 30-120VDC
    • Max. Solar Volt (VOC): 145VDC
    • Max Charge Current: 80A
  • Solar Inverter - 3kw Off Grid - MUST
    Translation missing: en.products.product.regular_price $285.00
  • Solar Inverter- OFF Grid Hybrid - MUST 5.2KVA
    Translation missing: en.products.product.regular_price $300.00
  • Solar Inverter- OFF Grid -MUST 10kw
    Translation missing: en.products.product.regular_price $720.00
  • Solar Inverter- On/OFF Grid -MUST 3 KW
    Translation missing: en.products.product.regular_price $400.00
  • Login