HYBRID INVERTER - 5.5KW/100A MPPT - SUNPAX BY SAKO

HYBRID INVERTER - 5.5KW/100A MPPT -  SUNPAX BY SAKO
Regular price $185.00

100A MPPT & Parrallel-able workable w/o battery

Model  SUNPAX 505KW
The rated power  5500VA/5500W
 INPUT                                           
Voltage  230 VAC
Selectable Voltage Range 170-280VAC(UPS),90-280VAC(Appliances)
Frequency Range 50Hz/60Hz(Auto sensing)

OUTPUT                                        

AC Voltage Regulation (Batt.Model)  230VAC+-5%
Surge Power 11000VA
Efficiency(Peak) >90%
Transfer Time 10MS(UPS).20MS(Appliances)
Wave form Pure sine wave
No load current 1.3A
 BATTERY                                     
Battery Voltage  48VDC
Low battery alarming voltage 44.0VDC
Low battery cut off protection voltage 42VDC
Low battery recovery voltage 46.0VDC
floating charge voltage 54VDC
Overcharge protection 64VDC
 MPPT SOLAR CHARGER & AC CHARGER   
Maximum PV Array power  5500W
MPPT range at operation Vol. 120-450VDC
Maximum PV array open circuit Vol. 500VDC
Number of MPPT trackers / Max output current 100A
Maximum AC Charge current 80A
Maximum charge current 100A
 BEST PANEL CONFIGUTATION        
Best panel configuration  300Wp*9pcs*30V(2700Wp)*2Parallel
 PHYSICAL                    
Products Dimension .D*W*H(mm)  498mm*313mm*123mm
Packing size D*W*H(mm) 577mm*395mm*217mm
Net weight (kgs) 10.0KG
G.w. kg 11.3KG
 OPERATING ENVIRONMENT     
Humidity  5% to 95% Relative Humidity (Non-condensing)
Operation temperature 0C.50C

100A MPPT & Parrallel-able workable w/o battery

Model  SUNPAX 505KW
The rated power  5500VA/5500W
 INPUT                                           
Voltage  230 VAC
Selectable Voltage Range 170-280VAC(UPS),90-280VAC(Appliances)
Frequency Range 50Hz/60Hz(Auto sensing)

OUTPUT                                        

AC Voltage Regulation (Batt.Model)  230VAC+-5%
Surge Power 11000VA
Efficiency(Peak) >90%
Transfer Time 10MS(UPS).20MS(Appliances)
Wave form Pure sine wave
No load current 1.3A
 BATTERY                                     
Battery Voltage  48VDC
Low battery alarming voltage 44.0VDC
Low battery cut off protection voltage 42VDC
Low battery recovery voltage 46.0VDC
floating charge voltage 54VDC
Overcharge protection 64VDC
 MPPT SOLAR CHARGER & AC CHARGER   
Maximum PV Array power  5500W
MPPT range at operation Vol. 120-450VDC
Maximum PV array open circuit Vol. 500VDC
Number of MPPT trackers / Max output current 100A
Maximum AC Charge current 80A
Maximum charge current 100A
 BEST PANEL CONFIGUTATION        
Best panel configuration  300Wp*9pcs*30V(2700Wp)*2Parallel
 PHYSICAL                    
Products Dimension .D*W*H(mm)  498mm*313mm*123mm
Packing size D*W*H(mm) 577mm*395mm*217mm
Net weight (kgs) 10.0KG
G.w. kg 11.3KG
 OPERATING ENVIRONMENT     
Humidity  5% to 95% Relative Humidity (Non-condensing)
Operation temperature 0C.50C
  • PV1800 VPM Series High Frequency Off Grid Solar Inverter (1KW)
  • Pure sine wave output
  • Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
  • Bult in MPPT 60A solar charge controller
  • Combining solar system, AC utility, and battery power source to supply continuous power
  • Overload, short circuit and Deep discharge protection
  • Cold start function
  • Support USB, RS485 monitoring function
  • WIFI remote monitoring (optional)
  • Compatible to generator

 

MODEL PV18-1012 VPM
Default Battery System Voltage 12VDC
INVERTER OUTPUT
Rated Power 1000VA / 1000W
Surge Power 2000VA
Waveform Pure sine wave
AC Voltage Regulation (Batt.Mode) 220VAC~240VAC(Setting)
Inverter Efficiency(Peak) 90%~93%
Transfer Time 10ms(UPS / VDE4105) / 20ms(APL)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE)
Frequency Range 50Hz / 60Hz (Auto sensing)
BATTERY
Normal voltage 12VDC
Floating Charge Voltage 13.7VDC
Overcharge Protection 15VDC
SOLAR CHARGER & AC CHARGER
Maximum PV Array Open Circuit Voltage 75VDC
PV Array MPPT Voltage Range 15~75VDC
Standby Power Consumption 2W
Maximum PV Array Power 625W
Maximum Solar Charge Current
Maximum Efficiency 98%
Maximum AC Charge Current 10A or 20A
Maximum Charge Current 70A
MECHANICAL SPECIFICATIONS
Machine Dimensions (W*H*D)(mm) 225*355*92
Package Dimensions (W*H*D)(mm) 410*300*78
Net Weight(kg) 5
Gross Weight(kg) 5.5
OTHER
Humidity 5% to 95% Relativ Humidity (Non-condensing)
Operating Temperature 0°C~50°C
Storage Temperature -15°C -60°C


  • Solar Inverter - 3KW - OFF GRID - MUST VPM
    Translation missing: en.products.product.regular_price $230.00
    • MUST ORIGINAL
    • Solar Inverter:
    • Model Name: PV1800
    • MD: PH18-3024 VPM
    • Operating Temp. Range: -10c ~50c
    • Protection Class: Class I
    • Protection Degree: IP 20
    • INVERTER MODE:
    • Rated Power: 3000VA/3000W
    • DC Input: 24VDC, 130A
    • AC Output: 220VAC, 50HZ 13A
    • Output Power Factor: 1.0
    • AC Charger Mode:
    • AC Input: 220VAC, 50Hz 17.7A
    • DC Output: 27VDC, 30/20A
    • Solar Charger Mode:
    • Rated Power: 60A
    • System Current: 24VDC
    • MPPT Volt Range: 30-120VDC
    • Max. Solar Volt (VOC): 145VDC
    • Max Charge Current: 80A
  • Solar Inverter - 3kw Off Grid - MUST
    Translation missing: en.products.product.regular_price $285.00
  • Solar Inverter- OFF Grid Hybrid - MUST 5.2KVA
    Translation missing: en.products.product.regular_price $300.00
  • Solar Inverter- OFF Grid -MUST 10kw
    Translation missing: en.products.product.regular_price $720.00
  • Solar Inverter- On/OFF Grid -MUST 3 KW
    Translation missing: en.products.product.regular_price $400.00
  • Login